12.
K-Factor Settings
Dispenser Settings
The following diagram displays how to change the dispenser settings, such as the meter type,
variant and minimum delivery. To get to the following menu, depress the K-Factor switch once
when not in a transaction. The menu shown is for side A if side B is required, continue
depressing the K-Factor switch until the same menu for side B is reached and follow the same
set up instructions.
These settings will likely be set in the factory. Only change the following settings if required. See
following pages for information on these settings.
-A
0000000
Meter Settings
1-1 Channel Encoder
2-2 Channel Encoder
3-3 Channel Encoder
4-V50 Meter
Variant Settings
0-Non-LPG
4- AdBlue (Diesel
Emissions Fluid)
5-LPG
Quantity Settings (V50 Meter
Only)
0-Litres Compensated
1-Litres Uncompensated
2-Mass (CNG only)
NOT USED
Minimum Measured
Quantity Exponent
Must be a valid digit-
see below
Minimum Measured
Quantity Coefficient
MUST be 1, 2 or 5
Air Settings
0-Normally open turn
air switch ON for error
1-Normally closed turn
air switch OFF for error