Changing the Temperature Calibration
The temperature calibration can be used to adjust the temperature being retrieved from the
meter, if this is not the actual temperature of the product being dispensed. The actual
temperature of product being dispensed should be entered in this menu. This will be used to
adjust new temperatures returned from the meter.
See Using the Dispenser Menus to edit these settings. Use the procedure for both side A and B.
As only V50 meters return temperature readings, this option is only for V50 operation and will
not appear if the meter is not set to V50.
Changing the Density Calibration
The density calibration can be used to adjust the density being retrieved from the meter, if this is
not the actual density of the product being dispensed. The actual density of product at 15 °C
being dispensed should be entered in this menu. This will be used to adjust new densities
returned from the meter.
See Using the Dispenser Menus to edit these settings. Use the procedure for both side A and B.
As only V50 meters return density readings, this option is only for V50 operation and will not
appear if the meter is not set to V50.