Service schedule: Fluid Force 2000 (2000 Hour oil change)
The bulkoil temperature must not exceed90°c (Fluid Force2000) or 100°c (Fluid Force HPO).Ifthe oil is working above this temperature, the
oil life will be reduced.
Note: When changing recommended oil types it is advisable to flush the compressor.
Page 6
CompAir Hydrovane
Introduction
Preventative Maintenance Schedule Fluid Force 2000/HPO
Maintenance Actions and Manual
Reference
Install
Every
Day
Every
Week
Every
1000
hrs
Every
2000
hrs
Every
6000
hrs
Every
12000
hrs
Every
24000
hrs
Suitable sited
3 33333
Adequate ventilation
3 33333
Ambient temperature
33333333
Sufficient access
3
Clear of airborne contaminants
33333333
Torque electrical connections
3 3333
Check oil level at filler plug 1C
3 33333
Check correct drive rotation
33
Check for air leaks
3 33333
Check for oil leaks
3 33333
Check air filter 1C
33
Check power on load
3 3333
Check power off load
3 3333
Check oil temperature 1B
33333333
Check RSU oil temperature
33333333
Check servo pressure on load
3 333333
Check servo pressure off load
3 333333
Check motor cable glands secure
3 3333
Check motor for damage 1C
3 3333
Check motor for loose connections 1C
3 3333
Check motor cables and earth 1C
3 3333
Check motor for vibration
3 3333
Check perishable oil pipes
3
Check oil seal 1C
333
Check drive media
333
Check operation of non-return valve
3 3333
Check RSU temperature
33333333
Check starter contactors
333
Check motor insulation resistance
3
Clean air/oil radiator external 1C
333333
Clean external dirt from motor 1C
3 333333
Clean cabinet air filter 1C
33
Clean solenoids
33333