JHT01 Service Manual
6-8
Any of the connectors may be disconnected. Perform Check 1.
Check 1
Disconnect the AC power cord from wall outlet. Check the power cable for
breaks.
If the power cord is damaged, connect a new AC power cord.
If there is no damage, go to Check 2.
Check 2
Make sure the AC adaptor cord and AC power cord are firmly plugged into the
DC-IN socket, AC adaptor inlet and wall outlet.
If these cables are connected correctly, go to Check 3.
Check 3
Make sure that the DC-IN input port socket is firmly secured to the system board
of the computer
If the DC-IN input socket is loose, go to Procedure 5.
If it is not loose, go to Check 4.
Check 4
Use a multimeter to make sure that the AC adaptor output voltage is close to 19 V.
If the output is several percent lower than 19 V, go to Check 5.
If the output is close to 19 V, go to Check 6.
Check 5
Connect a new AC adaptor or AC power cord.
If the battery LED does not light, go to Check 6.
Check 6
Make sure the battery pack is installed in the computer correctly.
If the battery is properly installed and the battery LED still does not light, go
to Procedure 4.
3.4 Procedure 4 Diagnostic check
The power supply may not charge the battery pack. Perform the following
procedures:
Reinstall the battery pack.
Attach the AC adaptor and turn on the power. If you cannot turn on the power,
go to Procedure 5.
Run the Diagnostic test following the procedures described Tests and
Diagnostics
. If no problem is detected, the battery is functioning normally.