Inverter should pass human body safety test.
Inverter should no smoking by any component open / short test
Transformer voltage stress should not be over 85% under any condition (turn
on overshoot transient and line transient).
Audio noise should be less than 36dB at 10 cm distance.
4.4 Electrical specification
4.4.1 Electrical specification
No Symbol Min. Type. Max. Unit Comment
V
oper
. -- 650 -- Vrms Lamp operating voltage (650+/-50)
I
L
6.2 6.5 6.8 mArms DAC_BRIG: 0 V, PWM: 100%
I
L
3.0 3.3 3.6 mArms DAC_BRIG: 0 V, PWM: 30%
I
L
5.7 6 6.3 mArms DAC_BRIG: 1 V, PWM: 100%
I
L
2.7 3 3.3 mArms DAC_BRIG: 1 V, PWM: 30%
f 45 55 65 KHz
1
η
80% -- -- --
4.4.2 Thermal
All components on inverter board should follow below rules:
Component using conditions (component stress) must be within component
specification including voltage rating, current rating, temperature etc.
Component temperature should follow below:
Δ T < 30°C, at 25, 35°C.
Component temperature should be less than 70
°C inside system at 35°C.
4.5 Connector description
4.5.1 Input Connector:
CN1: ACES 87213-0700; JST SM07B-SRSS-TB
Symbol Description
1 INV_PWR Input voltage (9V-21V)
2 INV_PWR Input voltage (9V-21V)
3 INV_PWM Adjust brightness by burst mode (3.3 V 150Hz)
4 DISOFF # Backlight on/off control, active HIGH (3.3V)