Infortrend
5-41
SCSI Drive Read/Write Test
From the “View and Edit SCSI Drives”
menu, select a new or used drive that
the utility is to be performed on; then
press ENT. Select “SCSI Drive
Utilities;" then press ENT. Choose
“Read/Write Test” and press ENT.
Press or to select and choose to
enable/disable the following options:
1. "Auto Reassign Bad Block;
2. Abort When Error Occurs;
3. Drive Test for - Read Only/Read
and Write.
When finished with configuration,
select "Execute Drive Testing" and
press ENT to proceed.
The Read/Write test progress will be
indicated as a percentage.
You may press ESC and select
"Read/Write Test" later and press or
to select to "View Read/Write
Testing Progress" or to "List Current
Bad Block Table." If you want to stop
testing the drive, select "Abort Drive
Testing" and press ENT to proceed.
Drive Read/Write
Test ..
Auto Reassign
Disabled ..
Abort When Error
Occur-Enabled
Drive Test for
Read and Write..
Execute Drive
Testing ..
Drv Testing 23%
Please Wait !
View Read/Write
Test Progress ..
List Current
Bad Block Table.
Abort Read/Write
Testing ..