EasyManua.ls Logo

Compaq External RAID Controller & Subsystem Infortrend - SCSI Channels Status

Compaq External RAID Controller & Subsystem Infortrend
347 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal Screen Messages
6-7
6.7 SCSI Channel’s Status
Chl
SCSI channel number
Mode
Channel mode
RCCom Redundant controller communication channel
Host Host Channel mode
Drive Drive Channel mode
PID
IDs managed by the Primary Controller
* Multiple IDs were applied (Host Channel mode only)
(ID
number)
Host channel:
Specific IDs managed by the Primary Controller for host
LUN mapping
Drive channel:
Specific ID reserved for the channel processor on the
Primary controller
SID
IDs managed by the Secondary Controller
* Multiple IDs were applied (Host Channel mode only)
(ID
number)
Host channel:
Specific IDs managed by the Secondary Controller for
host LUN mapping
Drive channel:
Specific ID reserved for the channel processor on the
Secondary controller; used in redundant controller mode
NA No SCSI ID applied
DefSynClk
Default SCSI bus synchronous clock:
??.?M The default setting of the channel is ??.? MHz in
Synchronous mode.
Async. The default setting of the channel is Asynchronous mode.
DefWid
Default SCSI Bus Width:
Wide 16-bit SCSI
Narrow 8-bit SCSI
S
Signal:
S Single-ended
LLVD
FFibre

Table of Contents