EasyManua.ls Logo

Compaq External RAID Controller & Subsystem Infortrend - Optimization Mode

Compaq External RAID Controller & Subsystem Infortrend
347 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Infortrend
2-11
Date and time
N/A
Time zone
+ 8 hrs
Optimization Mode:
Write-back Cache
Enabled Disabled
Array stripe size
Related to controller general
setting
4KB to 256KB
Optimization for
Random/Sequential
Sequential Either (sequential for LD larger than
512MB and can not be changed)
Array write policy
Related to controller general
setting
W/B or W/T
SCSI Parameters:
Data Transfer Rate
* Async. To 100.0MHz
Maximum Tag Count
32 1-128
Maximum Queued
I/O Count
32 32 to 1024
LUN’s per SCSI ID
8Up to 32
Periodic Drive Check
Time
Disabled Enabled
Periodic SAF-TE and
SES Device Check
Time
5 Disabled to 60 seconds
Periodic Auto-Detect
Failure Drive Swap
Check Time
Disabled 5 to 60 seconds
Number of Host-LUN
Connection
32 1 to 1024
Tag per Host-LUN
Connection
32 1 to 256
Wide Transfer
* Enabled/Disabled
Parity Check
Disabled Enabled
Spin-Up Parameters:
Motor Spin-Up
Disabled Enabled
Reset at Power-UP
Enabled Disabled
Initial Disk Access
Delay
* None to 75 seconds
Fibre Channel Parameters:
Fibre Connection
Options
* Loop Only
Point-to-Point Only
Loop Preferred
Point-to-Point Preferred
Fibre Channel Dual-
Loop
Enabled Enabled by cabling
Host ID/WWN name
list
* User configurable
LUN Filtering
* Host Access Filter Control
Configurable - filter type - access
right - name
RCC through Fibre
channel
* Dedicated or sharing drive channel(s)

Table of Contents