Infortrend
5-31
Press or to select “View and Edit
SCSI Target,” then press ENT.
Press or to select a SCSI target,
then press ENT.
Slot Number
To set the Slot number of the SCSI
target, choose “Slot Assignment," then
press ENT. The current slot number
will be displayed.
Press or to change the slot
number, then press ENT for two
seconds.
Maximum Synchronous Transfer Clock
Press or to select a SCSI target,
then press ENT.
To set the maximum synchronous
clock of this SCSI target, choose “Max.
Synchronous Xfer Clock," then press
ENT. The current clock setting will be
displayed on the LCD.
Press or to change the clock, then
press ENT for two seconds.
Maximum Transfer Width
Press or to select a SCSI target,
then press ENT.
To set the maximum transfer width of
this SCSI target, choose “Max. Xfer
Narrow Only” or “Max. Xfer Wide
Supported,” then press ENT. The
SCSI Target
CHL=1 ID=0 ..
SCSI Target
CHL=1 ID=0 ..
SCSI Target
CHL=1 ID=0 ..
Slot Assignment
Default No Set..
Max Synchronous
Xfer Clock# 12..
Max Xfer Wide
Supported ..
Slot Assignment
Set to # 9 ?
Period Factor
Def= 12 to
--
?

Table of Contents