EasyManua.ls Logo

Compaq External RAID Controller & Subsystem Infortrend - SCSI Drive Status

Compaq External RAID Controller & Subsystem Infortrend
347 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Infortrend
6-6
6.6 SCSI Drive Status
Slot
Slot number of the drive;
“S” indicates this is the drive used for passing through SES
signals
Chl
The drive channel where the drive is connected
X<Y> indicates two channels are configured in a dual-loop
ID
The channel ID assigned to this drive
Size (MB)
Drive capacity
Speed
XxMB Maximum transfer rate of drive channel interface
Async The drive is using asynchronous mode.
LG_DRV X
The drive is a drive member of logical drive x.
If the Status column shows “STAND-BY”, the drive
is a Local Spare of logical drive x.
Status Global
The SCSI drive is a Global Spare Drive
INITING
Processing array initialization
ON-LINE
The drive is in good condition
REBUILD
Processing Rebuild
STAND-BY
Local Spare Drive or Global Spare Drive. The
Local Spare Drive’s LG_DRV column will show
the logical drive number. The Global Spare
Drive’s LG_DRV column will show “Global”.
NEW DRV
A new drive has not been configured to any
logical drive or as a spare drive
USED DRV
An used drive that is not a member of any
logical drive or configured as spare
BAD
Failed drive
ABSENT
Drive does not exist
MISSING
Drive once existed, but is missing now
SB-MISS
Spare drive missing
Vendor and
Product ID
The vendor and product model information of
the drive

Table of Contents