EasyManua.ls Logo

Compaq External RAID Controller & Subsystem Infortrend - Idle Drive Failure Detection; Periodic Auto-Detect Failure Drive Swap Check Time

Compaq External RAID Controller & Subsystem Infortrend
347 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Infortrend
9-23
long as no host accesses that drive. Changing the check time to any
other value allows the controller to check – at the selected time
interval – all of the drives that are listed under “View and Edit SCSI
Drives.” If any drive is then removed, the controller will be able to
know – even if no host accesses that drive.
Idle Drive Failure Detection
Periodic Auto-Detect Failure Drive Swap Check Time
The “Drive-Swap Check Time” is the interval at which the controller
checks to see whether a failed drive has been swapped. When a
logical drive’s member drive fails, the controller will detect the
failed drive (at the selected time interval). Once the failed drive has
been swapped with a drive that has adequate capacity to rebuild the
logical drive, the rebuild will begin automatically.
The default setting is “Disabled,” meaning that the controller will
not Auto-Detect the swap of a failed drive. To enable this feature,
select a time interval.
Choose “Periodic Drive Check Time;” then press [ENTER]. Move
cursor to the desired interval; then press [ENTER]. Choose Yes in
the dialog box that follows to confirm the setting.

Table of Contents