EasyManua.ls Logo

Compaq External RAID Controller & Subsystem Infortrend - Environment Management; SAF-TE;S.E.S. Support

Compaq External RAID Controller & Subsystem Infortrend
347 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware Functionality Specifications
B-9
Environment Management:
SAF-TE/S.E.S. support
Supported. The SAF-TE/S.E.S. modules can be
connected to the drive channel, the controller will
detect errors from SAF-TE/S.E.S. devices or notify
drive failure via SAF-TE/S.E.S..
Both SAF-TE/S.E.S. via drive and device-self-
interfaced are supported.
Redundant SAF-TE/S.E.S. devices are
supported
Multiple S.E.S. devices are supported
Dynamic on-lining of
enclosure services
Once an expansion unit (JBOD) with supported
monitoring interface is combined with a RAID system,
its status will be automatically polled.
SAF-TE/S.E.S. polling
period
User configurable (50ms, 100ms, 200ms, 500ms,
1~60sec)
ISEMS (Infortrend Simple
Enclosure Management
Service)
Supported.
Multiple SAF-TE/S.E.S.
modules on the same
channel
Supported.
Multiple SAF-TE /S.E.S.
modules on different
channels
Supported.
Mapping SAF-TE/S.E.S.
device to host channel for
use with Host-based SAF-
TE/S.E.S. Monitor
Supported.
Dual-LED drive status
indicators
Supported. Both single-LED and dual-LED drive
status indicators are supported.
SAF-TE/ S.E.S. Temperature
value display
Supported. Display the temperature value provided
by enclosure SAF-TE module (if available).
Fault-bus support
Provides the simplest implementation for the
enclosure management. All fault-bus input/output
signals are active-high/active-low user adjustable.
On-board controller voltage
monitors
Supported. Monitors the 3.3V, 5V, and 12V voltage
status. Event trigger threshold user configurable.
On-board controller
temperature sensors
Supported. Monitors the CPU and board
temperature status. Event trigger threshold user
configurable.
Enclosure redundant power
supply status monitoring
Supported. Fault-Bus/SAF-TE/S.E.S./ISEMS
Enclosure Fan status
monitoring
Supported. Fault-Bus/SAF-TE/S.E.S/ISEMS
Enclosure UPS status
monitoring
Supported. Fault-Bus/SAF-TE/S.E.S/ISEMS
Enclosure temperature
monitoring
Supported. Fault-Bus/SAF-TE/S.E.S/ISEMS

Table of Contents