Infortrend
1-7
A Local Spare always has
higher priority than a
Global Spare.
Figure 1 - 12 Mixing Local and Global Spares
Logical Drive 0
Local Spare Drive
12
3
LS
Logical Drive 1
12
Logical Drive 2
12
3
4
Global Spare Drive
GS
(9GB)
(9GB)
(9GB)(9GB)
(4GB)
(4GB) (4GB)
(4GB) (4GB)
(4GB) (4GB)
In the example shown below, the member of Logical Drive 0 are 9
GB drives, and the members in Logical Drives 1 and 2 are 4 GB
drives.
It is not possible for the 4 GB Global
Spare Drive to join Logical Drive 0
because of its insufficient capacity.
However, using a 9GB drive as the
Global Spare drive for a failed drive that
comes from Logical Drive 1 or 2 will
bring huge amount of excess capacity
since these logical drives require 4 GB
only. In the diagram below, the 9 GB
Local Spare Drive will aid Logical Drive
0 once a drive in this logical drive fails. If
the failed drive is in Logical Drive 1 or 2,
the 4 GB Global Spare drive will
immediately give aid to the failed drive.