Description l 2-3
2
Description
Typical Applications (continued)
Model Drying Temperature Range
Low temperature (with precooler)* 10 - 150°F {38° - 66°C}
Standard 150° - 240°F {66° - 11C}
High heat (with aftercooler/intercooler)* 150° - 375°F {66° - 191°C}
Low-high (with aftercooler/intercooler & precooler)* 10 - 37F {3 - 191°C}
* See page 3-17, 3-18 and Appendix B
Throughput rates of 600 to 5000 lbs {271 to 454 kg} per hour (some
materials can be ran at a higher rate).
Dewpoints of -40°F {-40°C}.
Use the aftercooler/intercooler when:
You are drying at temperatures over 240°F {116°C}.
Throughput rates are less than 50% of the dryer’s rated capacity.
You are pre-drying material at temperatures over 150°F {66°C}
The return air is 12F {4C} or above.
Dryer Options
Dewpoint monitor/dewpoint control
Audible and visual alarm
NOTE: Temperature setback is only available in conjunction with the Hopper Temperature
Controller (HTC) or ResinWorks systems.
NOTE: The aftercooler/intercooler reduces the temperature of air returning from the drying hop-
per, improving the efficiency of the desiccant.
NOTE: Carousel Plus W Series 600-1000 Dryers use an aftercooler located before the the process
blower. Carousel Plus W Series 1600-5000 uses an intercooler located after the process blower.