EasyManua.ls Logo

Control Module Genus G1 Mark II - Reference; Steps to Re-Program Genus Firmware

Control Module Genus G1 Mark II
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Genus G1 MARK II Users Manual
UM3010-2
Reference
Steps to Re-Program Genus Firmware:
In the event an update becomes available for the Genus terminal, the firmware can be
updated in the field.
The following items are required to (re-)program Genus firmware:
Data terminal to be programmed, connected to the network
the IP address of the Genus terminal
computer / laptop connected to the network and able to PING the data terminal
Genus firmware
Genus (“System”) file update:
The Genus terminal application makes use of CMI Java classes and interfaces in the CMI
Genus API.
tftp –i <ip address> PUT Genus \flashdisk\Genus
(Note: Genus file name may be versioned (e.g. g2_3_3_12)
Classes (API) update:
The classes file is specific to your terminal type (G1 or G2). Check the release notes or other
documentation provided with the updated files to confirm the name of Classes.jar (may be
GI.jar or GII.jar).
tftp –i <ip address> PUT Classes.jar \flashdisk\Classes.jar
Note: The terminal will reboot after replacing the Genus or Classes files
Wait until the terminal reboots before sending additional files.
Confirming Updates:
To confirm that the Genus and/or Classes update(s) took place, follow the steps below:
1) Place the terminal in Offline mode
2) Locate the “Terminal Information” screen
3) Check “API:” to find Classes version.
4) Scroll to “Program Version:” to locate Genus Version.
Revision B 10-30-07 60