7. Menu 74 Parameters ALSPA PROFIBUS Field Bus Coupler
Page 7-12 Technical Manual (09/06)
Par No Name Default Range Attrib. Comment
P74.29 FBC1 Ref. 5 Fallback 0
±200.00 %
E
P74.30 FBC1 Reference 6 0
±200.00 %
E
P74.31 FBC1 Ref. 6 Fallback 0
±200.00 %
E
P74.32 FBC1 Reference 7 0
±200.00 %
E
P74.33 FBC1 Ref. 7 Fallback 0
±200.00 %
E
P74.34 FBC1 Reference 8 0
±200.00 %
E
P74.35 FBC1 Ref. 8 Fallback 0
±200.00 %
E
P74.36 FBC1 Reference 9 0
±200.00 %
E
P74.37 FBC1 Ref. 9 Fallback 0
±200.00 %
E
P74.38 FBC1 Reference 10 0
±200.00 %
E
P74.39 FBC1 Ref. 10 Fallback 0
±200.00 %
E
P74.40 FBC1 Control Word 1 0 0-FFFF E
P74.41 Control1 Fallback 1. 0 0-FFFF E
P74.42 FBC1 Control Word 2 0 0-FFFF E
P74.43 Control1 Fallback 2. 0 0-FFFF E
P74.50 FBC1 Rx Word 1 Ptr. 00.00 0-99.99 E.N *
P74.51 FBC1 Rx Word 1 Scale 0 0=Unity
1=Speed (%)
2=Speed (RPM)
3=Torque(%)
4=Torque(Nm)
5=Frequency
6= Percent
7=Speed Ramp Rate
8=Torque Slew Rate
9=Current
10=Volts
11=Resistance
12=Inductance
13=Scaler 1
14=Scaler 2
15=Scaler 3
E.L.*
P74.52 FBC1 Rx Word 2 Ptr. 00.00 0-99.99 E.N *
P74.53 FBC1 Rx Word 2 Scale 0 0-15 E.L.*
P74.54 FBC1 Rx Word 3 Ptr. 00.00 0-99.99 E.N *
P74.55 FBC1 Rx Word 3 Scale 0 0-15 E.L *
P74.56 FBC1 Rx Word 4 Ptr. 00.00 0-99.99 E.N *
P74.57 FBC1 Rx Word 4 Scale 0 0-15 E.L *
P74.58 FBC1 Rx Word 5 Ptr. 00.00 0-99.99 E.N *
P74.59 FBC1 Rx Word 5 Scale 0 0-15 E.L *
P74.60 FBC1 Rx Word 6 Ptr. 00.00 0-99.99 E.N *
P74.61 FBC1 Rx Word 6 Scale 0 0-15 E.L *
P74.62 FBC1 Rx Word 7 Ptr. 00.00 0-99.99 E.N *
P74.63 FBC1 Rx Word 7 Scale 0 0-15 E.L *
P74.64 FBC1 Rx Word 8 Ptr. 00.00 0-99.99 E.N *
P74.65 FBC1 Rx Word 8 Scale 0 0-15 E.L *
P74.66 FBC1 Rx Word 9 Ptr. 00.00 0-99.99 E.N *
P74.67 FBC1 Rx Word 9 Scale 0 0-15 E.L *
P74.68 FBC1 Rx Word 10 Ptr. 00.00 0-99.99 E.N *
P74.69 FBC1 Rx Word 10 Scale 0 0-15 E.L *
P74.70 FBC1 Tx Word 1 Ptr. 00.00 0-99.99 E.N *
P74.71 FBC1 Tx Word 1 Scale 0 0-15 E.L *