Refrigeration System
Page E20
CCM1030R
Ambients Refrigeration Pressures PSIG
Compressor Temps
°F
Cycle Times
°F
Discharge Suction Discharge Suction Minutes' Seconds"
Air/Water Start End Start Freeze End Freeze
Start
Harv
End
Harv
Start End Start End Freeze Harvest Complete
-20/40 240 240 61 33 94 101 104 159 53 38 6'44" 0'55" 7'39"
70/50 270 266 72 34 107 112 115 173 58 42 8'36" 0'55" 9'31"
90/70 287 272 77 33 111 117 118 182 60 43 10'21" 1'01" 11'22"
120/100 419 323 93 28 135 150 128 221 77 43 24'34" 0'55" 25'29"