Reference Guide DOC. 7150B 3-Series Control Systems 15
Update Local Password
To update the current user's password, issue the UPDATEPASSWORD command.
When authentication is enabled, users may update their password. The user is
prompted to enter the current password once and the new password twice. If the
old password does not match the current password, the operation fails and the
password is not changed.
Reset User Password
To reset a user's password, issue the RESETPASSWORD command.
Syntax: RESETPASSWORD -N:username -P:defaultpassword
o -N: Specifies the user whose password will be reset
o -P: Specifies a default password that can be provided to the user
following the reset
Example: RESETPASSWORD -N:jsmith1 -P:Default321!
Login Behavior
When authentication is enabled, users must enter a username and password to
connect to the control system.
A user is given a maximum of three login attempts for each type of transport
protocol (Ethernet, USB, and dynamic). If a user fails to authenticate against
console within the maximum attempts allowed, the transport protocol used to
attempt the connection is blocked.
For USB transport, the transport is blocked for 5 seconds after the
maximum logon attempt is reached. If the user tries again after 5 seconds
and continues to fail, the block time is doubled. The block time continues
to be doubled until a successful logon or control system reboot happens.
Once a user successfully authenticates against console, the failure count
is reset to zero, and the block time is reset to 5 seconds.
For Ethernet transport, after a remote IP fails to logon within maximum
attempts allowed, the console forces the transport to close and blocks
further logon attempts from that remote IP for 24 hours.
NOTE: To regain access to the control system from a blocked IP,
successfully log in to the console over USB, and then use the
REMBLOCKEDip console command to remove the blocked IP. For more
information, refer to “Blocked IP Address Functions” on page
18.
For dynamic transport (mainly used by console symbol), console
authentication is not required, and the user’s access level is granted by
default.

Other manuals for Crestron CP3N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crestron CP3N and is the answer not in the manual?

Crestron CP3N Specifications

General IconGeneral
Internal memory0.5 GB
Storage media typeFlash
Internal memory typeSDRAM
Internal storage capacity4 GB
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)24 W
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)10 - 90 %
Product colorBlack
Heat dissipation50 BTU/h
Housing materialMetal
Ethernet LAN (RJ-45) ports2
Weight and Dimensions IconWeight and Dimensions
Depth167 mm
Width439 mm
Height44 mm
Weight1420 g

Related product manuals