Reference Guide DOC. 7150B 3-Series Control Systems 43
Master-Slave Configuration
Use the following console commands to configure master-slave mode
parameters for the control system.
Add Master Entry
To add a master entry to the IP table, use the ADDMASTER command.
Syntax: ADDMASTER [cipid] -[ip_address/name]
o cipid: The ID of the CIP node (in hexadecimal format)
o ip_address/name: The IP address (in dot decimal notation) or the
name of the site for DNS lookup
Example: ADDMASTER 1E -PRO3-IH
Remove Master Entry
To remove a master entry from the IP table, use the REMMASTER command.
Syntax: REMMASTER [cipid] -[ip_address/name]
o cipid: The ID of the CIP node (in hexadecimal format)
o ip_address/name: The IP address (in dot decimal notation) or the
name of the site for DNS lookup
Example: REMMASTER 1E -PRO3-IH
View Master IP Table
To view the master IP table, use the MIPTABLE command. Append [-T] to the
command to output the results in table format.
View Slave Status
To display the status of the slave processor, use the SLAVESTATUS command.

Other manuals for Crestron CP3N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crestron CP3N and is the answer not in the manual?

Crestron CP3N Specifications

General IconGeneral
Internal memory0.5 GB
Storage media typeFlash
Internal memory typeSDRAM
Internal storage capacity4 GB
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)24 W
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)10 - 90 %
Product colorBlack
Heat dissipation50 BTU/h
Housing materialMetal
Ethernet LAN (RJ-45) ports2
Weight and Dimensions IconWeight and Dimensions
Depth167 mm
Width439 mm
Height44 mm
Weight1420 g