36 3-Series Control Systems Reference Guide DOC. 7150B
Firewall Rules in Normal Operation
Under normal operating procedures, the firewall on the control system router
behaves as follows.
Control System Firewall Rules - Normal Operation
DIRECTION PORT(S) RULE DESCRIPTION
Inbound from LAN 20, 21 To CPU FTP (if enabled)
Inbound from LAN 22 To CPU SSH
Inbound from LAN 80, 443 To CPU Web server (if enabled)
Inbound from LAN 843 To CPU Flash policy server (if enabled)
Inbound from LAN 41794-41797 To CPU Crestron communication protocols
Inbound from LAN
Listen ports
used by
program
To CPU Programmatic listeners
Inbound from LAN 64000-64299
To devices
on control
system
Allows Crestron management tools to access
devices on the Control Subnet; ports are
opened and closed as needed
Control Subnet
outbound to LAN
Any port Allowed All outbound traffic is allowed
Inbound from LAN User-defined
User-
defined
Allows manual port forwarding to devices on
Control Subnet
Firewall Rules in Isolation Mode
Under normal operating procedures, the firewall on the control system router
behaves as follows.
Control System Firewall Rules - Isolation Mode
DIRECTION PORT(S) RULE DESCRIPTION
Inbound from LAN 20, 21 To CPU FTP (if enabled)
Inbound from LAN 22 To CPU SSH
Inbound from LAN 80, 443 To CPU Web server (if enabled)
Inbound from LAN 843 To CPU Flash policy server (if enabled)
Inbound from LAN 41794-41797 To CPU Crestron communication protocols
Inbound from LAN
Listen ports
used by
program
To CPU Programmatic listeners
Inbound from LAN 64000-64299
Blocked
In isolation mode, Crestron management
tools cannot connect to any devices on the
Control Subnet
Control Subnet
outbound to LAN
Any port
All other
devices:
Blocked
No outbound traffic is allowed
Inbound from LAN User-defined Blocked
In isolation mode, no port forwarding can be
managed by the user

Other manuals for Crestron CP3N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Crestron CP3N and is the answer not in the manual?

Crestron CP3N Specifications

General IconGeneral
Internal memory0.5 GB
Storage media typeFlash
Internal memory typeSDRAM
Internal storage capacity4 GB
AC input voltage100-240 V
AC input frequency50 - 60 Hz
Power consumption (typical)24 W
Operating temperature (T-T)5 - 45 °C
Operating relative humidity (H-H)10 - 90 %
Product colorBlack
Heat dissipation50 BTU/h
Housing materialMetal
Ethernet LAN (RJ-45) ports2
Weight and Dimensions IconWeight and Dimensions
Depth167 mm
Width439 mm
Height44 mm
Weight1420 g

Related product manuals