The CS2325 Plug-on Adapter
The CS2325 Plug-on Adapter provides a connection between the CS2300-R
DualCom GPRS and Control Panels that have a facility for plug-on comms.
Power to the DualCom, connections to the DualCom’s 8 input channels, the
DualCom’s ATS Test input and the Fault output are all made via the plug-on
pins. See Fig 8 and appendix 3.
When the CS2325 Plug-on Adapter is used, the Control Panel must supply +5
volts and +12 volts from its plug-on pins.
Note 1: The CS2325 Plug-on Adapter is for use with Intruder Alarm sys-
tems only. The supply voltage must not exceede +15 volts.
19
Fig 8
Pin 1
Pin 1
Installation
1. Connect the Plug-on Adapter to the DualCom and the Control Panel. Refer
to the Plug-on Adapter leaflet.
Ensure that the Plug-on Adapter is connected to the Control Panel the cor-
rect-way-round. See the markings for ‘Pin1’ on the connectors and Fig 8.
2. Do not connect any power or supply voltage to the DualCom’s ‘9-30 volt’
Screw Terminals.
Mounting
Refer to the Plug-on Adapter leaflet.