User Manual Control Units
www.cuesystem.com
Page 24 of 44
3.8.4. RS-485 One-directional Output Connection
A device controlled via RS-485 can be connected as described below.
S 5 - S 9 RS-485 Port Description
Pin 1 B- Data - from Assistant or Assistant-S
Pin 2 A+ Data + from Assistant or Assistant-S
Signal Ground
Signal Output
1 432
Assistant or Assistant-S
S 5 to S 9
Controlled Device
RS-485
B-
A+
GND