P 125 N 99 CY __
Th: __.__ __.__ Kg/mm²
p/d _/_ CR __/ri __.__
--MEM-- --POS-- --COR--
__._°
Y1 ___.__ 350.92 ___.__
Introduce 99 and press the key.
1st sequence Introduce the thickness, the sigma, the tools as below:
To select a tool, enter the tool number or press
when the cursor
is in the P or M field to display the tool list.
Select the tool in the list and press
again to go back to the
sequence page.
P 0 N 1 CY __
Th: 2.00 σ 37.00 Kg/mm²
p/d 1/1 CR __/ri __.__
Program 90 in the field.
By leaving the field, the system calculates the Y1 and Y2 axes' values.
Introduce 58.0 in the X field (stop position for this first bend).
Introduce the bending length 1000.
The system calculates the pressure and the crowning automatically.
If necessary, introduce the dwell time (by default non-programmed =
0.5 s), the gauge retraction, the bending speed reduction, the slow
raising, etc.
Press
and then 1, in order to copy this first sequence in
sequence 2.
The message COPIED is displayed, the N field passes on 2.
The LED of the key remains lighted, indicating that you are on the
last sequence.