DES-1228/ME Layer 2 Metro Ethernet Switch CLI Reference Manual
280
42
LOOPBACK DETECTION COMMANDS
The Loopback Detection commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the
following table.
Command Parameters
config loopdetect { recover_timer [0 | <value 60-1000000>] | interval <value 1-32767>}(1)
config loopdetect ports [<portlist> | all] state [enable | disable]
enable loopdetect
disable loopdetect
show loopdetect
show loopdetect ports [<portlist> | all]
Each command is listed, in detail, in the following sections.
config loopdetect
Purpose Used to configure loopback detection on the switch.
Syntax
config loopdetect { recover_timer [0 | <value 60-1000000>] | interval <value 1-
32767>}(1)
Description Used to configure loopback detection on the switch.
Parameters
recover_timer The time interval (in seconds) used by the Auto-Recovery mechanism to
decide how long to check if the loop status is gone. The valid range is 60 to 1000000. Zero
is a special value which means to disable the auto-recovery mechanism. The default value is
60.
interval The time interval (in seconds) at which the remote device transmits all the CTP
packets to detect the loopback event. The default value is 10, with a valid range of 1 to
32767.
Restrictions Only Administrator-level users can issue this command.
Example usage:
To set the recover time to 0, and interval to 20:
DES-1228/ME:4#config loopdetect recover_timer 0 interval 20
Command: config loopdetect recover_timer 0 interval 20
Success