DES-1228/ME Layer 2 Metro Ethernet Switch CLI Reference Manual
53
Example Usage:
To disable SNMP link changing traps:
DES-1228/ME:4#disable snmp linkchange_traps
Command: disable snmp linkchange_traps
Success.
DES-1228/ME:4#
config snmp coldstart_traps
Purpose Used to configure cold start SNMP traps.
Syntax
config snmp coldstart_traps [enable|disable]
Description Used to configure cold start SNMP traps.
Parameters
[enable|disable] Choose enable or disable to enable or disable this function.
Restrictions Only Administrator-level users can issue this command.
Example Usage:
To enable config snmp coldstart_traps:
DES-1228/ME:4#config snmp coldstart_traps enable
Command: config snmp coldstart_traps enable
Success.
DES-1228/ME:4#
config snmp warmstart_traps
Purpose Used to configure warm start SNMP traps.
Syntax
config snmp warmstart_traps [enable|disable]
Description Used to configure warm start SNMP traps.
Parameters
[enable|disable] Choose enable or disable to enable or disable this function.
Restrictions Only Administrator-level users can issue this command.
Example Usage:
To enable config snmp warmstart_traps:
DES-1228/ME:4#config snmp warmstart_traps enable
Command: config snmp warmstart_traps enable
Success.