Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 1
Page 3.3.10
during takeoff
ITT HI
1 - Continue takeoff normally.
When takeoff procedure is completed :
If AT is engaged :
2 - AT Disconnect. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 - THROTTLE Reduce. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To get ITT < 820°C
● NOTE ●
Above 400 ft AGL, autothrottle engine protection system will reduce power to
get ITT below 820°C. The resulting engine power is sufficient to maintain
minimum climb gradients.
●
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS