Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 2
Page 3.9.4
and 1/3
MAIN GEN LOW VOLTAGE
an
With GENERATOR selector on ST-BY (after MAIN generator failure), functioning on
ST-BY generator.
1 - GENERATOR selector MAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - MAIN GENERATOR RESET push-button Press. . . . . . . . . . . . . . . . . . . . . . . .
► Fly the airplane ◄
If MAIN GENERATOR successfully connected :
3 - Disconnect non-essential systems.
4 - Voltmeter and ammeter Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
► Land as soon as possible ◄
End of procedure ■
If MAIN GENERATOR not successfully connected :
5 - GENERATOR selector ST-BY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 - ST-BY GENERATOR RESET push-button Press. . . . . . . . . . . . . . . . .
If ST-BY GENERATOR successfully connected :
7 - Disconnect non-essential systems.
8 - Voltmeter and ammeter Monitor. . . . . . . . . . . . . . . . . . . . . . . . . .
► Land as soon as possible ◄
End of procedure ■
If ST-BY GENERATOR not successfully connected :
Both generators failure is confirmed.
Return to VMC conditions, if possible.
Continue ►