EasyManua.ls Logo

Daher TBM 940 - 3.10 Pressurization and Air Conditioning

Default Icon
946 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.10.1
3.10 - Pressurization and air conditioning
PRESSU OFF
1/2
Possibly due to :
- system malfunction,
- BLEED switch on OFF position.
If in flight :
1 - Oxygen masks Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - BLEED switch Check / Correct. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If possible :
3 - TRQ Reduce. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fly the airplane
4 - BLEE
D switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 - BLEED switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If PRESSU OFF is still ON :
If altitude > 10000 ft :
If necessary :
6 - Perform procedure Emergency descent. . . . . . . .
Refer to chapter 3.6
7 - Continue the flight.
NOTE
If Zp > 10000 ft ± 500 ft, it may be followed by CABIN ALTITUDE and
USE OXYGEN MASK
Inform ma
intenance department.
End of procedure
Continue
PIM - DO NOT USE FOR FLIGHT OPERATIONS

Table of Contents