Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.11.5
Windshield misting or internal icing
Symptoms : mist or ice on windshield internal face.
1 -
TEMP
selector Set to 12 o’clock position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - HOT AIR FLOW distributor Turn to the left. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 - DE ICE SYSTEM mode switch MAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
All deicing systems turn on
4 - WINDSHIELD switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
▲ WARNING ▲
If icing conditions, turn deicing systems on.
▲
5 - INERT SEP switch As required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 - AIRFRAME DE ICE switch As required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 - PROP DE ICE switch As required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If unsuccessful, to get sufficient visibility :
8 - HOT AIR FLOW distributor Fully turn to the left. . . . . . . . . . . . . . . . . . .
9 - Manually clean a sufficient visibility area.
If necessary :
▲ CAUTION ▲
In case of sideslip approach with pedal on the right during a long
period, select R.H. fuel tank.
▲
10 - Clean L.H. side window.
11 - Perform a sideslip approach with rudder pedals to the right.
To get sufficient landing visual references
For landing :
12 - FLAPS lever LDG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13 - Airspeed Maintain above 95 KIAS. . . . . . . . . . . . . . . . . . . . . . . . .
End of procedure.