Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 3
Page 3.8.8
>> With HomeSafe emergency function (Post-MOD70-0650-34A)
HS FUEL SHUTOFF
Indicates that the HomeSafe fuel shut-off valve is closed.
WARNING
This may quickly lead to an engine stop if the right fuel tank is
selected.
1 - FUEL TANK SELECTOR L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 - AUX BP switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE
Maintain AUX BP switch in ON position for the remainder of the flight.
Land as soon as practical
If HS FUEL SHUTOFF remains ON :
A mechanical failure of the HomeSafe fuel shut-off valve may have occurred.
3 - FUEL SEL switch MAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 - FUEL TANK SELECTOR Check L. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAUTION
Land as soon as possible to limit fuel imbalance.
End of procedure.