Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.6.4
Maximum range descent 2/2
► Continuing
19 - AP / TRIMS OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 - DIMMER / CABIN / ACCESS OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If icing conditions :
21 - PITOT L/R & STALL HTR switch ON. . . . . . . . . . . . . . . . . . . . .
22 - WINDSHIELD switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23 - Airspeed Above 135 KIAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration flaps UP
If time permits :
24 - PLUG
S breakers Pull. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25 - AIR COND breaker Pull. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26 - Prepare for Forced landing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refer to chapter 3.7
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS