Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 3.7.9
Emergency gear extension 3/3
Continuing
If :
- emergency pump remains soft or
- one (or more) green light(s) is(are) not ON and / or flickering while pressing
the CHECK DOWN push-button :
A gear unlock condition is confirmed.
Recycle the landing gear as follows :
12 - By-pass selector Unlock / Push. . . . . . . . . . . . . . . . . . . . . . . . . . .
13 - Wait one minute.
14 - LANDING GEAR lever UP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
At airspeed < 150 KIAS
15 - Perform landing gear extension attempts in the normal mode
while ap
plying positive load factors during the maneuver as well
as skidding.
In case of failure :
16 - Perform procedure Landing with unlocked. . . . . . . . . . . .
main landing gear
or Landing with defective nose landing gear
Refer to following procedures
CAUTION
If one main landing gear is not down, it is recommended to land with
landing gear up - refer to procedure Landing with gear up in the
following procedures.
End of procedure.