Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 0 - March 05, 2019
Rev. 0
Page 4.4.26
Engine start 3/3
► Continuing
Abort starting procedure if :
- No ignition 10 seconds after having positioned THROTTLE to
LO-IDLE,
- lights on (max ITT < 870°C for more than 20 seconds,
< 1000°C for more than 5 seconds),
- Ng < 30 % after 30 seconds of starter use,
- Ng < 50 % after 60 seconds of starter use,
13 - THROTTLE CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 - IGNITION switch OFF or AUTO. . . . . . . . . . . . . . . . . . . .
When ITT < 850°C :
15 - STARTER switch ABORT. . . . . . . . . . . . . . . . . . .
End of procedure ■
ITT
When
- Ng > 50 % and,
- 1 minute max :
▲ CAUTION ▲
If the starter does not go off automatically, disengage it using the
ABORT position of the STARTER switch.
▲
16 - Starter Check OFF automatically. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17 - STARTER Check OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 - Engine parameters Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Check 54 % ≤ Ng ≤ 58 %, oi
l pressure and ITT in green sector
End of procedure.