Pilot's Operating Handbook
Section 7
Description
Edition 0 - March 05, 2019
Rev. 2
Page 7.10.13
Cabin
override
Selecting the switch to PILOT position disables TEMP and FAN speed selectors in the
cabin area.
The PILOT position also distributes warm air equally to the cockpit and cabin.
Only the cockpit TEMP and FAN selectors inputs are used by the GASC for air
temperature management.
Air temperature
expectations
Cockpit panel selection Cabin panel selection
Cockpit
area
Warm
Cabin
area
/
Results
Mixed Bleed Air Circuit :
Warm air is distributed equally to both cockpit and cabin. The temperature is selected by the
cockpit TEMP selector.
Cold Air Circuit :
Not active, as the cockpit TEMP selector is set in the red zone and cabin TEMP selector is
inhibited.
Cockpit FAN : select 0. Selecting a FAN speed will reduce cabin air temperature.
PIM - DO NOT USE FOR FLIGHT OPERATIONS