ulse/kWh
A.2.2.F.5 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.F.6 [D-04] R/O
0: No
1: Yes
└─ Capacities
A.2.3.1 [6-02] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.2 [6-03] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.3 [6-04] R/W 0~10kW, step: 0,2kW
0kW
└─ Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1 [9-01] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.1.2.2 [9-00] Temperature range Maximum temp (heating) R/W 37~55°C, step: 1°C
55°C
A.3.1.1.2.3 [9-03] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.1.2.4 [9-02] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
A.3.1.1.5 [8-05] R/W 0: No
1: Yes
A.3.1.1.7 [9-0B] R/W
0: Quick
1: Slow
└────────────────── Additional
A.3.1.2.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1 [9-05] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.2.2.2 [9-06] Temperature range Maximum temp (heating) R/W 37~55°C, step: 1°C
55°C
A.3.1.2.2.3 [9-07] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.2.2.4 [9-08] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
└────────────────── Delta T source
A.3.1.3.1 [9-09] R/W 3~10°C, step: 1°C
5°C
Emitter type
Heating
LWT setpoint mode
External sensor
PCC by digital inputs
BUH: step 1
BUH: step 2 (*1)(*2)
LWT setpoint mode
Modulated LWT
Booster heater
Preferential kWh rate
Contact type main
Ext. backup heat src
Alarm output
External kWh meter 1
External kWh meter 2
DHW operation
Contact type add.
Pump operation mode
Power saving possible
User interface location
External sensor
Backup heater steps
BUH type
DHW pump
Glycol present
Number of LWT zones