Daikin Altherma EBLQ011CA3V3 - Page 134

Daikin Altherma EBLQ011CA3V3
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3/8
Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
A.2.1.8 [7-02] R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9 [F-0D] R/W 0: Continuous
1: Sample
2: Re
q
ues
t
A.2.1.A [E-04] R/O
0~1
0: No
A.2.1.B R/W 0: At unit
1: In room
A.2.1.C [E-0D] R/W
0: No
1: Yes
└─ Options
A.2.2.A [D-02] R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.2.2.B [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
└────────────────── Control box
A.2.2.E.1 [E-03] R/W
R/O (*3)(*4)
0: No BUH (*1) (*2)
1: 1 step (*3) (*4)
2: 2 ste
p
s
A.2.2.E.2 [5-0D] R/W
R/O (*3)(*4)
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,
(
1/1+2
)
A.2.2.E.3 [D-01] R/W
0: No
1: Open tariff
2: Closed tariff
A.2.2.E.4 [E-05] R/W
0: No
1: Yes
A.2.2.E.5 [C-05] R/W
1: Thermo ON/OFF
2: C/H re
q
uest
A.2.2.E.6 [C-06] R/W 0~2
1: Thermo ON/OFF
└────────────────── Option box
A.2.2.F.1 [C-02] R/W
0~3
0
A.2.2.F.2 [C-09] R/W
0: Normally open
1: Normall
y
closed
A.2.2.F.3 [D-08] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.2.2.F.4 [D-09] R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.2.2.F.5 [C-08] R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.F.6 [D-04] R/O
0: No
1: Yes
└─ Capacities
A.2.3.1 [6-02] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.2 [6-03] R/W 0~10kW, step: 0,2kW
3kW
A.2.3.3 [6-04] R/W 0~10kW, step: 0,2kW
0kW
└─ Space operation
└─ LWT settings
└────────────────── Main
A.3.1.1.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1 [9-01] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.1.2.2 [9-00] Temperature range Maximum temp (heating) R/W 37~55°C, step: 1°C
55°C
A.3.1.1.2.3 [9-03] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.1.2.4 [9-02] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
A.3.1.1.5 [8-05] R/W 0: No
1: Yes
A.3.1.1.7 [9-0B] R/W
0: Quick
1: Slow
└────────────────── Additional
A.3.1.2.1 R/W 0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1 [9-05] Temperature range Minimum temp (heating) R/W 15~37°C, step: 1°C
25°C
A.3.1.2.2.2 [9-06] Temperature range Maximum temp (heating) R/W 37~55°C, step: 1°C
55°C
A.3.1.2.2.3 [9-07] Temperature range Minimum temp (cooling) R/W 5~18°C, step: 1°C
5°C
A.3.1.2.2.4 [9-08] Temperature range Maximum temp (cooling) R/W 18~22°C, step: 1°C
22°C
└────────────────── Delta T source
A.3.1.3.1 [9-09] R/W 3~10°C, step: 1°C
5°C
Emitter type
Heating
LWT setpoint mode
External sensor
PCC by digital inputs
BUH: step 1
BUH: step 2 (*1)(*2)
LWT setpoint mode
Modulated LWT
Booster heater
Preferential kWh rate
Contact type main
Ext. backup heat src
Alarm output
External kWh meter 1
External kWh meter 2
DHW operation
Contact type add.
Pump operation mode
Power saving possible
User interface location
External sensor
Backup heater steps
BUH type
DHW pump
Glycol present
Number of LWT zones
(*1) *B*CAV3/CAW1_
(*2) *D*CAV3/CAW1_
(*3) *B*CA3*_(*4) *D*CA3*
4P522033-1A - 2018.06