Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
A.3.1.3.2 [9-0A] R/W 3~10°C, step: 1°C
5°C
└─ Room thermostat
A.3.2.1.1 [3-07] Room temp. range Minimum temp (heating) R/W 12~18°C, step: A.3.2.4
16°C
A.3.2.1.2 [3-06] Room temp. range Maximum temp (heating) R/W 18~30°C, step: A.3.2.4
30°C
A.3.2.1.3 [3-09] Room temp. range Minimum temp (cooling) R/W 15~25°C, step: A.3.2.4
15°C
A.3.2.1.4 [3-08] Room temp. range Maximum temp (cooling) R/W 25~35°C, step: A.3.2.4
35°C
A.3.2.2 [2-0A] R/W -5~5°C, step: 0,5°C
0°C
A.3.2.3 [2-09] R/W -5~5°C, step: 0,5°C
0°C
A.3.2.4 R/W 0: 0,5 °C
1: 1 °C
└─ Operation range
A.3.3.1 [4-02] R/W 14~35 °C, step: 1°C
35°C
A.3.3.2 [F-01] R/W 10~35°C, step: 1°C
20°C
└─ Domestic hot water (DHW)
└─ Type
A.4.1 [6-0D] R/W 0: Reheat only
1: Reheat + Scheduled
2: Scheduled onl
y
└─ Disinfection
A.4.4.1 [2-01] R/W 0: No
1: Yes
A.4.4.2 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
A.4.4.3 [2-02] R/W 0~23 hour, step: 1 hour
23
A.4.4.4 [2-03] R/W 55~75°C, step: 5°C
70°C
A.4.4.5 [2-04] R/W 5~60 min, step: 5 hour
10
└─ Maximum set point
A.4.5 [6-0E] R/W If [E-07]=0
40~75°C, step: 1°C
60°C
If [E-07]=5
40~80°C, step: 1°C
80
°
C
└─ SP mode
A.4.6 [2-01] R/W
0: Fixed
1: Weather de
p
.
└─ Weather dependent curve
A.4.7 [0-0B] R/W 35~[6-0E]°C, step: 1°C
55°C
A.4.7 [0-0C] R/W 45~[6-0E]°C, step: 1°C
60°C
A.4.7 [0-0D] R/W 10~25°C, step: 1°C
15°C
A.4.7 [0-0E] R/W -40~5°C, step: 1°C
-10°C
└─ Heat sources
└─ Backup heater
A.5.1.1 [4-00] R/W 0~2
0: Disabled
1: Enabled
A.5.1.3 [4-07] R/W 0: No
1: Yes
A.5.1.4 [5-01] R/W -15~35°C, step: 1°C
-4°C
└─ System operation
└─ Auto restart
A.6.1 [3-00] R/W 0: No
1: Yes
└─ Preferential kWh rate
A.6.2.1 [D-00] R/W
0~3
0: None
1: BSH only
2: BUH only
3: All heaters
A.6.2.2 [D-05] R/W 0: Forced off
1: As normal
└─ Averaging time
A.6.4 [1-0A] R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Ext amb. sensor offset
A.6.5 [2-0B] R/W -5~5°C, step: 0,5°C
0°C
└─ Boiler efficiency
A.6.A [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
└─ Emergency
Allowed heaters
Forced pump OFF
Enable BUH step 2 (*1)(*2)
Equilibrium temp.
Start time
Temeperature target
Duration
Operation day
Weather-dependent curve
Weather-dependent curve
Space heating OFF temp
Space cooling On temp
Weather-dependent curve
Operation mode
Weather-dependent curve
Disinfection
Cooling
Room temp. offset
Ext. room sensor offset
Room temp. step