2 | Components
Service manual
70
(C)(F)TXA15~50A(W)(S)(T) + (C)(F)TXA15~50B(B)(S)(T) + RXA42+50A +
RXA20~35A + RXA42+50B
Split Stylish R32
ESIE18-03C – 2020.02
a Indoor unit fan motor cover
4 Put the switch box in place.
a Grouding wire cover screw
b Grounding wire screw
c Heat exchanger thermistor
d Indoor unit PCB
e Switch box screw
f Switch box
5 Route the connectors of the indoor unit fan motor and front wiring inside the
switch box and connect them to the indoor unit PCB.
6 Install and tighten the screw to secure the switch box.
7 Install the heat exchanger thermistor in its holder.
8 Connect the grounding wire to the heat exchanger using the screw.
9 Install the grounding wire cover using the screw.
Is the problem solved? Action
Yes No further actions required.
No Return to the troubleshooting of the
specific error and continue with the
next procedure.