Diagnosis by Malfunction Code SiE-05C
128 Troubleshooting Inverter K Series
2. Diagnosis by Malfunction Code
2.1 Diagnosis by Malfunction Code
Malfunction code Malfunction contents Fan operation Page
A0 Indoor unit: Error of external protection device 130
A1 Indoor unit: PC board defect 131
A3 Indoor unit: Malfunction of drain level control system (33H) 132
A6 Indoor unit: Fan motor (M1F) lock, overload 133
A7 Indoor unit: Malfunction of swing flap motor (M1S) 134
A9 Indoor unit: Malfunction of moving part of electronic expansion valve
(Y1E)
135
AF Indoor unit: Drain level above limit 136
AJ Indoor unit: Malfunction of capacity determination device 136
C4 Indoor unit: Malfunction of thermistor (R2T) for liquid pipe 137
C5 Indoor unit: Malfunction of thermistor (R3T) for gas pipes 137
C9 Indoor unit: Malfunction of thermistor (R1T) for air inlet 138
CJ Indoor unit: Malfunction of thermostat sensor in remote controller 138
E0 Outdoor unit: Actuation of safety device 139
E1 Outdoor unit: PC board defect 139
E3 Outdoor unit: Actuation of high pressure switch 140
E4 Outdoor unit: Actuation of low pressure switch 141
E9 Outdoor unit: Malfunction of moving part of electronic expansion
valve (Y1E)
142
F3 Outdoor unit: Abnormal discharge pipe temperature 143
H9 Outdoor unit: Malfunction of thermistor for outdoor air (R1T) 144
J3 Outdoor unit: Malfunction of discharge pipe thermistor (R3T) 144
J5 Outdoor unit: Malfunction of thermistor (R4T) for suction pipe 145
J6 Outdoor unit: Malfunction of thermistor (R2T) for heat exchanger 145
JA Outdoor unit: Malfunction of discharge pipe pressure sensor 146
JC Outdoor unit: Malfunction of suction pipe pressure sensor 147
JH Outdoor unit: Malfunction of oil temperature thermistor (R5T) 148
U0 Low pressure drop due to refrigerant shortage or electronic
expansion valve failure
149
U1 Negative phase, open phase 150
U2 Power supply insufficient or instantaneous failure 166
U4 Malfunction of transmission between indoor units 151
U5 Malfunction of transmission between remote controller and indoor
unit
152
U7 Malfunction of transmission between outdoor units 153
U8 Malfunction of transmission between master and slave remote
controllers
154
U9 Malfunction of transmission between indoor and outdoor units in the
same system
155
UA Excessive number of indoor units 156
UC Address duplication of central remote controller 156
UF Refrigerant system not set, incompatible wiring/piping 157
UH Malfunction of system, refrigerant system address undefined 158
SI-05C.BOOK Page 128 Monday, November 6, 2000 4:13 PM