VLT
®
MICRO
Multi-function output terminal operation (d01 and d08)
Pr.48 Output Frequency Offset
(can be programmed while the dirve is running)
Factory Setting d0.00
Units 0.1 Hz
Parameter value d0.0 - d350.0 Hz
Pr.49 Process Signal Bias
(can be programmed while the dirve is running)
Factory Setting d00
Units none
Parameter value d00 (minimum output frequency corresponds to 0 V, 4 mA)
d01 (minmum output frequency corresponds to potential bias)
Pr.50 Process Signal Gain
Factory Setting d100
Units 1%
Parameter value d01 - d200%
Pr.51 Process Signal Reverse Motion
Factory Setting d00
Units none
Parameter value d00 (forward motion only)
d01 (reverse motion enabled)
Detective Range
± 2Hz
ON
ON
OFF
OFF
Setting Freq.
Desired Freq.
Setting
Pre-set Freq.
attained indication
Desired Freq.
Attained Setting
P47
P45/46
P45/46
Detective Range
± 4Hz
Inefficient Range
– 2Hz
43