No. Parameter Function Parameter Factory
Name Explanation Value Setting
59 Activation Time for Electronic d30 - d300 sec d60
Thermal Protection Function
60 Over-torque Over-torque d00:Over-torque detection not d00
Detection detection mode enabled
d01:Over-torque detection during
constant speed operation.
Drive operation halted after
over-torque (OL2).
d02:Over-torque detection during
constant speed operation.
Operation continues after
over-torque detection (OL2).
d03:Over-torque detection during
operation.
Drive operation halted after
over-torque (OL2).
d04:Over-torque detection during
operation.
Operation continues after
over-torque detection (OL2).
61 Over-torque d30 - d200% d150
detection level
62 Over-torque d0.1 - d10.0 sec d0.1
detection time
63 Reserved
64 User Defined Displays user d00:Displays the drive output d06
Parameter defined parameter frequency (H)
Displayed on digital keypad/ d01:Display user-define setting (V)
display d02:Display user-define setting (r)
d03:Display user-define setting (L)
d04:Display user-define setting (%)
d05:Display the counter value (c)
d06:Display the program freq. (F)
d07:Display the par. setting (Pr.00)
d08:Reserved
d09:Displays motor current (A)
d10:Displays Fwd/Rev mode
65 Coefficient K Coefficient for line d0.1 - d160. d1.0
speed
select
66