15. Reconnect the machine function if disconnected earlier.
16. Start the prime mover, checking to ensure the pump remains in neutral.
17. Check for forward and reverse machine operation, with the prime mover at normal operating speed.
Charge pressure may decrease slightly during forward or reverse operation.
18. Continue to cycle slowly between forward and reverse for at least five minutes.
19. Shut down prime mover.
20. Remove gauges.
21. Plug the gauge ports.
22. Check reservoir level.
23. Add filtered fluid to the reservoir, if needed.
The motor / transmission is now ready for operation.
Service Manual
Series 51 and 51-1 Motors
Initial startup procedures
28 |
©
Danfoss | March 2016 11008567 | AX00000013en-US0202