AK-UI55 display menu (SW ver. 1.2x)
If the operation is protected by one or more passwords, reading and setting the parameter will be limited to:
R or W
This setting can be seen with password no. _ or higher (3 is the highest level).
This setting can be performed with password no. _ or higher (3 is the highest level).
The asterisk indicates in which application from 1-8 the parameter is applicable
Thermostat
Table 9: Thermostat
Function
Values
R-W
Code
1
2
3
4
5
6
7
8
Min.value
Max.value
Fact.value
Cut-out 1
0-0
r00
*
*
*
*
*
*
*
*
r03
r02
2.0 °C
Dierential 1
1-2
r01
*
*
*
*
*
*
*
*
0,1 °C
20.0 °C
2.0 °C
Max cut-out limit
0-2
r02
*
*
*
*
*
*
*
*
r03
50.0 °C
50.0 °C
Min cut-out limit
0-2
r03
*
*
*
*
*
*
*
*
-50.0 °C
r02
-50.0 °C
Display readout adjustment
1-2
r04
*
*
*
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
Temperature unit
0=Celsius, 1=Fahrenheit
1-2
r05
*
*
*
*
*
*
*
*
0
1
0
S4 Air OFF evap. A - Adjust-
ment
1-2
r09
*
*
*
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
S3 Air ON evap. A - Adjust-
ment
1-2
r10
*
*
*
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
S5 Evaporator A - Adjust-
ment
0-2
r11
*
*
*
*
*
*
*
*
-10.0 °C
10.0 °C
0.0 °C
Main switch
-1=Manual, 0=Stop, 1=Start
0-2
r12
*
*
*
*
*
*
*
*
-1
1
0
Night oset
1-2
r13
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
0.0 °C
Thermostat mode
2=Modulating, 1=ON/OFF
0-X
r14
*
*
*
*
*
*
*
*
1
2
1
Thermostat sensor S4 %
1-2
r15
*
*
*
*
*
*
*
*
0 %
100 %
100%
Melt interval
1-2
r16
*
*
*
*
*
*
*
*
0 h
10 h
1 h
Melt period
1-2
r17
*
*
*
*
*
*
*
*
0 min
30 min
5 min
Cut-out 2
0-2
r21
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
2.0 °C
Thermostat sensor S4 %
night
1-2
r61
*
*
*
*
*
*
*
*
0 %
100 %
100%
Air heater neutral zone
1-2
r62
*
*
*
*
0.0 °C
50.0 °C
5.0 °C
Air heater start delay
1-2
r63
*
*
*
*
0 min
240 min
240min
Food type
0=None, 1=Vegetables,
2=Dairy, 3=Meat and sh,
4=Frozen food, 5=Ice cream
1-2
(1)
r89
*
*
*
*
*
*
*
*
0
5
0
Dierential 2
1-2
r93
*
*
*
*
*
*
*
*
0.1 °C
20.0 °C
2.0 °C
S4 frost protection
1-2
r98
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
-50.0 °C
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
Alarm settings
Table 10: Alarm settings
Function
Values
R-W
Code
1
2
3
4
5
6
7
8
Min.value
Max.value
Fact.value
Alarm delay A
1-2
A03
*
*
*
*
*
*
*
*
0 min
240 min
30 min
Door open alarm delay
1-2
A04
*
*
*
*
*
*
*
*
0 min
240 min
60 min
Alarm delay pull down A
1-2
A12
*
*
*
*
*
*
*
*
0 min
240 min
90 min
High alarm limit 1
1-2
A13
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
8.0 °C
Low alarm limit 1
1-2
A14
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
-30.0 °C
High alarm limit 2
1-2
A20
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
8.0 °C
Low alarm limit 2
1-2
A21
*
*
*
*
*
*
*
*
-50.0 °C
50.0 °C
-30.0 °C
Alarm delay DI 1
1-2
A27
*
*
*
*
*
*
*
*
0 min
240 min
30 min
Alarm delay DI 2
1-2
A28
*
*
*
*
*
*
*
*
0 min
240 min
30 min