DI signal force cond. fan
1.
2.
3.
Figure 25: Condenser fan control
Appliance cleaning
This function makes it easy for the shop’s sta to carry out a cleaning of the appliance according to a standard
procedure. Appliance cleaning is activated via a pulse signal – as a rule via a key switch placed on the appliance or
via the AK-CC55 Connect mobile app.
Appliance cleaning is carried out via three activations:
At the rst activation, the refrigeration is stopped, but the fans keep on operating in order to defrost the
evaporators. ”Fan” is shown on the display.
At the second activation, the fans are also stopped and the appliance can now be cleaned. ”OFF” is shown on the
display.
At the third activation, refrigeration is recommenced. The display will show the actual appliance temperature,
o97 setting.
When appliance cleaning is activated, a cleaning alarm is transmitted to the normal alarm recipient. A later
processing of these alarms will document that the appliance has been cleaned as often as planned.
There are no temperature alarms during appliance cleaning.
Table 1: Appliance cleaning function
Appliance shutdown
The function is used to shut down an appliance for a peiod of time e.g. over a weekend. The cooling appliance is
stopped like the “Main switch”, but this happens without an “A45 standby alarm”. The function can be enabled by a
switch on the DI input or via a setting through data communication.
Defrost control
Defrost method
The following defrost methods can be selected:
0: None
AK-CC55 Water Loop
© Danfoss | Climate Solutions | 2022.04 BC378540472015en-000101 | 18