Installation and User Guide DEVIreg™ Multi
FEC | Produced by Danfoss © 39
O4 #2 Set On Time 1 0 15 min. RW 3029
O5 #2 Set PR Period (max. 900 minutes) 0 900 30 min. RW 3030
W4 Channel #2 > Alarm Temps & En/Dis
O6 #2 Alarm Temp En/Dis 0 1 0 – Dis Enum 5 RW 3031
O7 #2 Alarm min. Temp -50 0 0 °C RW 3032
O8 #2 Alarm max. Temp 0 200 60 °C RW 3033
W5 Channel #2 > CableOK?
O9 #2 CableOK? En/Dis - Enable or Disable the
function of current monitoring in the load
0 1 0 – Dis Enum 5 RW 3034
O10 #2 CableOK? = NO/NC. Set up DI2 status
Normally Opened (NO) or Normally Closed (NC)
when cable is OK
0 1 1 – NO Enum 8 RW 3035
W75 Power calculator > Channel Power #2
O11 #2 Channel Power (max. 32000) 0 32000 0 W RW 3036
W8 Channel #2 > Manually On/Of
O12 #2 Manually On/Of Time – Set up period of time
for MOn or MOf status (max. 900 minutes)
1 900 1 min. RW 3037
O13 #2 Status On or Of for mode Heating Manually 0 1 0 – Of Enum 11 RW 3038
O14 #2 Manually On/Of Start or Stop control mode.
Caution: this mode may cause overheating and
damage!
0 1 0 – STOP Enum 6 RW 3039
W9 Channel #2 > Channel ON/OFF
O15 #2 Channel ON/OFF If OFF – symbol # in the
line, algorithm is stopped, but real Temp. is
being shown
0 1 0 – OFF Enum 7 RW 3040
W11 Channel #2 > Sensor type
O17 #2 Sensor type 0 7 1 – PT1000 Enum 9 RW 3041
W12 Channel #2 > Relay Status RO/RC
O18 #2 Relay status - Set up Relay Opened (RO) or
Relay Closed (RC) for status ‘Heating On’
0 1 0 – RC Enum 10 RW 3042
W13 Channel #2 > Relay Test 5/30 sec.
O19
#2 Relay Test 5/30 - Every 5 sec. switching for 30 sec.
0 1 0 – STOP Enum 6 RW 3043
R1 Channel #3 > Regulation Type
I1 #3 Regulation Type: 1S – Single Sensor,
PR – Power Regulation
0 1 1 – 1S Enum 1 RW 3044
R2 Channel #3 > Temp & Hysteresis
I2 #3 Set Temperature -50 200 5 °C RW 3045
I3 #3 Set +-Hysteresis 0.2 6 0.4 °C RW 3046
R3 Channel #3 > On Time & Period
I4 #3 Set On Time 1 0 15 min. RW 3047
I5 #3 Set PR Period (max. 900 minutes) 0 900 30 min. RW 3048
R4 Channel #3 > Alarm Temps & En/Dis
I6 #3 Alarm Temp En/Dis 0 1 0 – Dis Enum 5 RW 3049
I7 #3 Alarm min. Temp -50 0 0 RW 3050
I8 #3 Alarm max. Temp 0 200 60 RW 3051