106 | © Danfoss | August 2018 AQ00000211
ENGINEERING TOMORROW
Figure 54
If P3714 is set to 1000 IR, the mixing factor 100 % will be considered for calculation of adjusted flow set-point.
As per default, P3714 and P3716 are both set to 10. Having these parameters set to the same value cancel out any
crossover ramping. To enable the function, set P3714 and P3716 to a value between 0 and 1000 to indicate the crossover
start (P3714) and crossover stop (P3716).
Name
Address
Data type
Unit
Description of parameter
User
Range
Danfoss default
value
Safety critical
parameters ‘S’
Min.
Max.
AUX anti-jerk function P3698 U8 -
Defines the type of the anti-jerk functionality to
use 0 for Anti Jerk type NONE and 1 for Anti Jerk type 1
OEM 0 1 0
AUX relative set-point
change, in towards spool
neutral position
P3699 U8 %
Relative set-point change allowed to apply when ramping the spool
position set-point out, i.e. further out from the spool neutral position [%]
OEM 0 100 5
AUX relative set-point
change, out from spool
neutral position
P3700 U8 %
Relative set-point change allowed to apply when ramping the spool
position set-point in, i.e. towards the spool neutral position [%]
OEM 0 100 5
AUX absolute set-point
change, in towards spool
neutral position
P3701 U16 IR
Set-point change allowed to apply when ramping the spool position set-
point out, i.e. further out from the spool neutral position
OEM 1 1000 10
AUX absolute set-point
change, out from spool
neutral position
P3703 U16 IR
Set-point change allowed to apply when ramping the spool position set-
point in, i.e. towards the spool neutral position
OEM 1 1000 15
AUX anti-jerk cross-
over start point
P3714 U16 IR AUX Anti-jerk Cross-over start OEM 1 1000 10
AUX anti-jerk cross-
over stop point
P3716 U16 IR AUX Anti-jerk Cross-over stop OEM 1 1000 10
AUX anti-jerk low pass
filter cut-off frequency
P3718 U8 dHz
AUX Anti-jerk low pass filter cut-off frequency
Resolution: 1 dHz = 0.1 Hz
OEM 5 200 100
Table 45

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals