106 | © Danfoss | August 2018 AQ00000211
Figure 54
If P3714 is set to 1000 IR, the mixing factor 100 % will be considered for calculation of adjusted flow set-point.
As per default, P3714 and P3716 are both set to 10. Having these parameters set to the same value cancel out any
crossover ramping. To enable the function, set P3714 and P3716 to a value between 0 and 1000 to indicate the crossover
start (P3714) and crossover stop (P3716).
Name
Description of parameter
Range
Safety critical
parameters ‘S’
AUX anti-jerk function P3698 U8 -
Defines the type of the anti-jerk functionality to
use 0 for Anti Jerk type NONE and 1 for Anti Jerk type 1
OEM 0 1 0
change, in towards spool
P3699 U8 %
Relative set-point change allowed to apply when ramping the spool
position set-point out, i.e. further out from the spool neutral position [%]
OEM 0 100 5
change, out from spool
P3700 U8 %
Relative set-point change allowed to apply when ramping the spool
position set-point in, i.e. towards the spool neutral position [%]
OEM 0 100 5
change, in towards spool
P3701 U16 IR
Set-point change allowed to apply when ramping the spool position set-
point out, i.e. further out from the spool neutral position
OEM 1 1000 10
change, out from spool
P3703 U16 IR
Set-point change allowed to apply when ramping the spool position set-
point in, i.e. towards the spool neutral position
OEM 1 1000 15
AUX anti-jerk cross-
over start point
P3714 U16 IR AUX Anti-jerk Cross-over start OEM 1 1000 10
AUX anti-jerk cross-
over stop point
P3716 U16 IR AUX Anti-jerk Cross-over stop OEM 1 1000 10
AUX anti-jerk low pass
filter cut-off frequency
P3718 U8 dHz
AUX Anti-jerk low pass filter cut-off frequency
Resolution: 1 dHz = 0.1 Hz
OEM 5 200 100
Table 45