17.4.15 OEM Data
PVED-CLS reserves 100 bytes of EEPROM memory locations from address P4212 to P4311 for OEMs, system integrators
can use these memory addresses to store their own data like serial ID or identification data.
This EEPROM memory section is not CRC protected and no validation will be done by PVED-CLS.
Important
The addresses P4210 and P4211 are reserved for future use and shall not be used.
17.5 CRC SECTOR
17.5.1 CRC sector overview
(bytes)
CRC/Checksum
calculation end
address
address
PSAC
Read/Write
Valve Calibration Data
CAN WAS Calibration Data
Analog Sensor Calibration Data
Vehicle Geometry
Production/Calibration Flag
Auto Calibration Config
Table 78
Warning
Danfoss recommends not modifying data outside the specified address ranges shown in Table 78 as it will be
detected by the PVED-CLS and lead to safe state!