11.7 OPEN LOOP SOFT STOP
The soft-stop function applies to all Open Loop configurations and limits the allowed maximum flow delivered to the
steering cylinders in proportion to the relative wheel angle and is mirrored to both sides (left- and right-end stop). The
function’s control algorithm will implement a linear interpolation between two points, Point A and Point B.
Point A (1000-P3710, 1000)
Point B (1000-P3712, P3708)
Figure 55
The range is from 100 to 1000 [IR] for P3708 (i.e. relative soft-stop flow limit).
The range is from 0 to 1000 [IR] for P3710 and P3712 (i.e. relative wheel angle).
The Danfoss recommended values are P3708 set to 200, and P3710 and P3712 set to 0. Soft stop functionality is
disabled with default values.
Important
For wheel angles lower than the one specified at Point A, maximum flow is available.
Point A
Point B
0
200
400
600
800
1000
1200
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
|Wheel Angle [IR]|
Soft Stop flow limit [IR]
AUX open loop soft stop

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals