ENGINEERING TOMORROW
Name
Address
Data type
Unit
Description of parameter
User
Range
Danfoss default
value
Safety critical
parameters ‘S’
Min.
Max.
GPS - Max flow @
Point D
P3451 U16 IR
Auto-guidance mode
Maximum allowed flow at the vehicle speed of 0 km/h
OEM 0 1000 1000 S
GPS - Vehicle speed
limiting flow @ Point E
P3453 U16 km/h
Auto-guidance mode
Vehicle speed at which the flow should be limited to @ Point E
OEM 0 100 15 S
GPS - Max flow @
Point E
P3455 U16 IR
Auto-guidance mode
Maximum allowed flow at the vehicle speed @ Point E
OEM 0 1000 50 S
GPS - Vehicle speed
limiting flow @ Point F
P3457 U16 km/h
Auto-guidance mode
Vehicle speed at which the flow should be limited to @ Point F
OEM 0 100 25 S
GPS - Max flow @
Point F
P3459 U16 IR
Auto-guidance mode
Maximum allowed flow at the vehicle speed @ Point F
OEM 0 1000 25 S
Table 57