EasyManua.ls Logo

Danfoss PVED-CLS - Page 131

Danfoss PVED-CLS
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Danfoss | August 2018 AQ00000211 | 131
ENGINEERING TOMORROW
Name
Address
Data type
Unit
Description of parameter
User
Range
Danfoss default
value
Safety critical
parameters ‘S’
Min.
Max.
GPS - Max wheel angle
speed @ Point D
P3451 U16 dDeg/s
Auto-guidance mode
Maximum allowed wheel angle speed at the vehicle speed of 0 km/h, @
Point D
OEM 0 1000 1000 S
GPS - Vehicle speed
limiting wheel angle
speed @ Point E
P3453 U16 km/h
Auto-guidance mode
Vehicle speed at which the wheel angle speed should be limited, @ Point E
OEM 0 100 15 S
GPS - Max wheel angle
speed @ Point E
P3455 U16 dDeg/s
Auto-guidance mode
Maximum allowed wheel angle speed @ Point E
OEM 0 1000 50 S
GPS - Vehicle speed
limiting wheel angle
speed @ Point F
P3457 U16 km/h
Auto-guidance mode
Vehicle speed at which the wheel angle speed should be limited @ Point F
OEM 0 100 25 S
GPS - Max wheel angle
speed @ Point F
P3459 U16 dDeg/s
Auto-guidance mode
Maximum allowed wheel angle speed @ Point F
OEM 0 1000 25 S
Table 58