EasyManua.ls Logo

Danfoss PVED-CLS - Page 145

Danfoss PVED-CLS
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Danfoss | August 2018 AQ00000211 | 145
ENGINEERING TOMORROW
Category SPN Signal Name Failure mode
FMI
Severity
Possible root cause(s)
Software 520229 Soft error Soft error detected
31
- Condition exists Severe
Internal failure
Software 520213 SPI Communication
Connection loss
11
- Unknown root-cause Severe
Internal failure
SPI message queue full
2 - Data erratic, intermittent or
incorrect
Severe
Internal failure
Software 1557 RAM test RAM-code test fails
12 - Bad intelligent device or
component
Severe
Internal failure
Software 520579 EEPROM VPS data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520232 EEPROM Hydraulic config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520233 EEPROM SEHS FDA
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520234
EEPROM Valve calibration
data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520235
EEPROM CAN WAS
Calibration data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations – see section 17.4.4
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520236
EEPROM Analogue Sensor
Calibration data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations – see section 17.4.5
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1.
Incorrect Approval CRC
Software 520237 EEPROM Peripherals config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations – see section 17.4.6
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520238 EEPROM SEHS Protocol data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520239 EEPROM Internal monitoring
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520241 EEPROM Vehicle geometry
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520242 EEPROM GPS config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations – see section 12
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1.
Incorrect Approval CRC
Software 520243 EEPROM STW config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations – see section 10
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520244 EEPROM AUX config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations – see section 11
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520245
EEPROM Auto-Calibration
config sector
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1.
Incorrect Approval CRC
Software 520246
Invalid sensor configuration
Invalid sensor configuration
31
– Condition exists Severe
If parameter settings are not done as per section
6.1.1
Software 299005 Software Initialization
Fault in software
configuration or initialization
process
11
- Unknown root-cause Severe
Internal
failure
Software 299004 Division by zero Division by zero
11
- Unknown root-cause Severe
Internal failure
Software 628 Flash test Flash test failure
12 - Bad intelligent device or
component
Severe
Internal failure
Software 299002 Variable truncation Variable truncation
11
- Unknown root-cause Severe
Internal failure
Software 299001 I2C communication I2C communication failure
12 - Bad intelligent device or
component
Severe
Internal failure

Table of Contents