Category SPN Signal Name Failure mode
FMI
Severity
Possible root cause(s)
Software 520229 Soft error Soft error detected
31
- Condition exists Severe
Internal failure
Software 520213 SPI Communication
Connection loss
11
- Unknown root-cause Severe
Internal failure
SPI message queue full
2 - Data erratic, intermittent or
incorrect
Severe
Internal failure
Software 1557 RAM test RAM-code test fails
12 - Bad intelligent device or
component
Severe
Internal failure
Software 520579 EEPROM VPS data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520232 EEPROM Hydraulic config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520233 EEPROM SEHS FDA
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520234
EEPROM Valve calibration
data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520235
EEPROM CAN WAS
Calibration data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations see section 17.4.4
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520236
EEPROM Analogue Sensor
Calibration data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations see section 17.4.5
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1.
Incorrect Approval CRC
Software 520237 EEPROM Peripherals config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations see section 17.4.6
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520238 EEPROM SEHS Protocol data
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520239 EEPROM Internal monitoring
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520241 EEPROM Vehicle geometry
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520242 EEPROM GPS config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations see section 12
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1.
Incorrect Approval CRC
Software 520243 EEPROM STW config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations see section 10
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520244 EEPROM AUX config
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1. Parameter setting out of range
2.
Illegal parameter combinations see section 11
3. Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1. Incorrect Approval CRC
Software 520245
EEPROM Auto-Calibration
config sector
Parameter value out of
range/Incorrect configuration
of EEPROM data
2
- Data erratic, intermittent or
incorrect
Severe
1.
Parameter setting out of range
2.
Incorrect sector CRC
Approval CRC failure
14
- Special instructions Severe
1.
Incorrect Approval CRC
Software 520246
Invalid sensor configuration
Invalid sensor configuration
31
Condition exists Severe
If parameter settings are not done as per section
6.1.1
Software 299005 Software Initialization
Fault in software
configuration or initialization
process
11
- Unknown root-cause Severe
Internal
failure
Software 299004 Division by zero Division by zero
11
- Unknown root-cause Severe
Internal failure
Software 628 Flash test Flash test failure
12 - Bad intelligent device or
component
Severe
Internal failure
Software 299002 Variable truncation Variable truncation
11
- Unknown root-cause Severe
Internal failure
Software 299001 I2C communication I2C communication failure
12 - Bad intelligent device or
component
Severe
Internal failure

Table of Contents

Other manuals for Danfoss PVED-CLS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PVED-CLS and is the answer not in the manual?

Danfoss PVED-CLS Specifications

General IconGeneral
BrandDanfoss
ModelPVED-CLS
CategoryController
LanguageEnglish

Related product manuals